{"product_id":"ev150-arx-e-n4ht","title":"EV150+ARX-E N4HT","description":"\u003cp\u003eConfigurable Electr. 2-way PI-CCV Belimo Energy Valve™, AC\/DC 24 V, BACnet\/IP, BACnet MS\/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 1 1\/2 [40], Internal thread, V'nom 44 GPM, 14...250°F [-10...120°C] , NEMA 4, UL Enclosure Type 4, Thermostat heater\u003c\/p\u003e\n\n\u003cp\u003eSpecifications:\u003cbr\u003e\n- List Price: $7,270.00\u003cbr\u003e\n- Control Mode: Flow Control Power Control Position Control Differential Pressure Control\u003cbr\u003e\n- Input (Y3) Range: 0.5-10V 2-10V Additional Sensor\u003cbr\u003e\n- Input (Y3) Setup: Not inverted Inverted\u003cbr\u003e\n- Output (U5) Range: 0-10V 0.5-10V 2-10V\u003cbr\u003e\n- Installation Position: Supply Pipe Return Pipe\u003cbr\u003e\n- dT Limiting Status: off dT Manager dT Manager Scaling\u003cbr\u003e\n- dT Limiting Temperature (°C\/F): 2°F \/ 1.1°C 3°F \/ 1.7°C 4°F \/ 2.2°C 5°F \/ 2.8°C 6°F \/ 3.3°C 7°F \/ 3.9°C 8°F \/ 4.4°C 9°F \/ 5.0°C 10°F \/ 5.6°C 11°F \/ 6.1°C 12°F \/ 6.7°C 13°F \/ 7.2°C 14°F \/ 7.8°C 15°F \/ 8.3°C 16°F \/ 8.9°C 17°F \/ 9.4°C 18°F \/ 10.0°C 19°F \/ 10.6°C 20°F \/ 11.1°C 21°F \/ 11.7°C 22°F \/ 12.2°C 23°F \/ 12.8°C 24°F \/ 13.3°C 25°F \/ 13.9°C 26°F \/ 14.4°C 27°F \/ 15.0°C 28°F \/ 15.6°C 29°F \/ 16.1°C 30°F \/ 16.7°C 31°F \/ 17.2°C 32°F \/ 17.8°C 33°F \/ 18.3°C 34°F \/ 18.9°C 35°F \/ 19.4°C 36°F \/ 20.0°C 37°F \/ 20.6°C 38°F \/ 21.1°C 39°F \/ 21.7°C 40°F \/ 22.2°C 41°F \/ 22.8°C 42°F \/ 23.3°C 43°F \/ 23.9°C 44°F \/ 24.4°C 45°F \/ 25.0°C 46°F \/ 25.6°C 47°F \/ 26.1°C 48°F \/ 26.7°C 49°F \/ 27.2°C 50°F \/ 27.8°C 51°F \/ 28.3°C 52°F \/ 28.9°C 53°F \/ 29.4°C 54°F \/ 30.0°C 55°F \/ 30.6°C 56°F \/ 31.1°C 57°F \/ 31.7°C 58°F \/ 32.2°C 59°F \/ 32.8°C 60°F \/ 33.3°C 72°F \/ 40.0°C 84°F \/ 46.7°C 89°F \/ 49.4°C\u003cbr\u003e\n- Electr. Interface Power Supply: 1m Plenum\u003cbr\u003e\n- Configured Total: $7,270.00\u003cbr\u003e\n- Pattern: 2-way\u003cbr\u003e\n- Flow: 44\u003cbr\u003e\n- Fluid: Chilled or hot water, up to 60% glycol max (open loop\/steam not allowed)\u003cbr\u003e\n- Fluid temperature: 14...250°F [-10...120°C]\u003cbr\u003e\n- Differential pressure: ∆p 5...50 psi\u003cbr\u003e\n- Body Pressure Rating: 360 psi\u003cbr\u003e\n- End Fitting: Internal thread\u003cbr\u003e\n- Trim: Stainless steel\u003cbr\u003e\n- Valve Size: 1.5\" [40]\u003cbr\u003e\n- Voltage AC\/DC: AC\/DC 24 V\u003cbr\u003e\n- Power Consumption (Running): 26 W\u003cbr\u003e\n- Power Consumption For Wire Sizing: 30 VA\u003cbr\u003e\n- Connection Ethernet: RJ45 socket\u003cbr\u003e\n- Control Type: BACnet\/IP BACnet MS\/TP Modbus TCP Modbus RTU MP-Bus DC 2...10 V DC 0.5...10 V Cloud\u003cbr\u003e\n- Degree Of Protection NEMA: NEMA 4\u003cbr\u003e\n- Enclosure Type: UL Enclosure Type 4\u003c\/p\u003e\n\n\u003cp\u003eDownloads \u0026amp; Manuals:\u003cbr\u003e\n- View download folder: https:\/\/www.belimo.com\/us\/shop\/en_US\/downloadcenter\/downloadfolder\u003cbr\u003e\n- Download Center: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\u003cbr\u003e\n- Product Documents: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/product-documents\u003cbr\u003e\n- Software\/Plug-Ins\/Apps: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/software-plug-in-apps\u003cbr\u003e\n- Success Stories: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/success-stories\u003cbr\u003e\n- Corporate: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/corporate\u003cbr\u003e\n- Images\/Videos\/Logos: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/images-videos-logos\u003cbr\u003e\n- Product Guide and Price List (PGPL): https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/pgpl-us\u003cbr\u003e\n- Terms and Conditions of Sale and Warranty: https:\/\/www.belimo.com\/us\/en_US\/support-am\/download-center\/term-conditions\u003cbr\u003e\n- Learn More: https:\/\/www.belimo.com\/us\/en_US\/products\/valves\/product-documentation\/energy-valve\u003cbr\u003e\n- Technical data sheet – EV150+ARX-E N4HT: https:\/\/www.belimo.com\/mam\/general-documents\/datasheets\/en-us\/belimo_EV150_ARX-E_N4HT_datasheet_en-us.pdf\u003cbr\u003e\n- Installation instructions - EV4 N4: https:\/\/www.belimo.com\/mam\/general-documents\/installation-instructions\/belimo_EV4_N4_installation_instructions.pdf\u003cbr\u003e\n- Belimo Clear Edge Brochure: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/control_valves\/belimo_clear-edge_brochure_en-us.pdf\u003cbr\u003e\n- Belimo Energy Valve Application Guide: https:\/\/www.belimo.com\/mam\/americas\/technical_documents\/Support%20material\/Belimo_Energy_Valve_Application_Guide.pdf\u003cbr\u003e\n- Belimo Energy Valve Manual - Differential Pressure Control: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/control_valves\/Differential-pressure-control.pdf\u003cbr\u003e\n- Communication Brochure: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/control_valves\/belimo_communication_brochure_en-us.pdf\u003cbr\u003e\n- EV 4.0 Operations Manual: https:\/\/www.belimo.com\/mam\/americas\/technical_documents\/Tech%20docs\/belimo_ev-4.0-operations_manual_en-us.pdf\u003cbr\u003e\n- Energy Valve Brochure: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/control_valves\/belimo_energy-valve_brochure_en-us.pdf\u003cbr\u003e\n- Flow Reduction Chart EV \u0026amp; EPIV: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/control_valves\/flow-reduction-chart.pdf\u003cbr\u003e\n- Optimal Flow for Direct-To-Chip Cooling With the Belimo Energy Valve: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/brochures\/flyer_direct-to-chip_brochure_en-us.pdf\u003cbr\u003e\n- BACnet Interface description – Belimo Energy Valve™ (for application software version 4.2.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/BACnet\/belimo_BACnet_Interface-description_Energy-Valve_V4_2_2_en-gb.pdf\u003cbr\u003e\n- Cloud Connection Guide: https:\/\/www.belimo.com\/mam\/europe\/technical-documentation\/technical-leaflets\/belimo_applications\/belimo_guide_cloud-connection_en-gb.pdf\u003cbr\u003e\n- MP-Bus Data-Pool Values – Belimo Energy Valve™ (for application software version 4.2.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/MP-Bus\/belimo_Data-Pool-Values_Energy-Valve_V4_2_2_en-gb.pdf\u003cbr\u003e\n- Modbus Interface description – Belimo Energy Valve™ (for firmware version 4.2.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/Modbus\/belimo_Modbus-Register_Energy-Valve_V4_2_2_en-gb.pdf\u003cbr\u003e\n- BACnet Interface description – Belimo Energy Valve™ (for application software version 4.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/BACnet\/belimo_BACnet_Interface-description_Energy-Valve_V4_1_en-gb.pdf\u003cbr\u003e\n- BACnet Interface description – Belimo Energy Valve™ (for application software version 4.1.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/BACnet\/belimo_BACnet_Interface-description_Energy-Valve_V4_1_1_en-gb.pdf\u003cbr\u003e\n- BACnet Interface description – Belimo Energy Valve™ (for application software version 4.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/BACnet\/belimo_BACnet_Interface-description_Energy-Valve_V4_2_en-gb.pdf\u003cbr\u003e\n- BACnet Interface description – Belimo Energy Valve™ (for application software version 4.2.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/BACnet\/belimo_BACnet_Interface-description_Energy-Valve_V4_2_1_en-gb.pdf\u003cbr\u003e\n- MP-Bus Data-Pool Values – Belimo Energy Valve™ (for application software version 4.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/MP-Bus\/belimo_Data-Pool-Values_Energy-Valve_V4_1_en-gb.pdf\u003cbr\u003e\n- MP-Bus Data-Pool Values – Belimo Energy Valve™ (for application software version 4.1.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/MP-Bus\/belimo_Data-Pool-Values_Energy-Valve_V4_1_1_en-gb.pdf\u003cbr\u003e\n- MP-Bus Data-Pool Values – Belimo Energy Valve™ (for application software version 4.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/MP-Bus\/belimo_Data-Pool-Values_Energy-Valve_V4_2_en-gb.pdf\u003cbr\u003e\n- MP-Bus Data-Pool Values – Belimo Energy Valve™ (for application software version 4.2.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/MP-Bus\/belimo_Data-Pool-Values_Energy-Valve_V4_2_1_en-gb.pdf\u003cbr\u003e\n- Modbus Interface description – Belimo Energy Valve™ (for firmware version 4.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/Modbus\/belimo_Modbus-Register_Energy-Valve_V4_1_en-gb.pdf\u003cbr\u003e\n- Modbus Interface description – Belimo Energy Valve™ (for firmware version 4.1.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/Modbus\/belimo_Modbus-Register_Energy-Valve_V4_1_1_en-gb.pdf\u003cbr\u003e\n- Modbus Interface description – Belimo Energy Valve™ (for firmware version 4.2): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/Modbus\/belimo_Modbus-Register_Energy-Valve_V4_2_en-gb.pdf\u003cbr\u003e\n- Modbus Interface description – Belimo Energy Valve™ (for firmware version 4.2.1): https:\/\/www.belimo.com\/mam\/general-documents\/system_integration\/Modbus\/belimo_Modbus-Register_Energy-Valve_V4_2_1_en-gb.pdf\u003cbr\u003e\n- Infographic - Land O'Lakes, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_land-o-ake_Infografik_success-story_es-us.pdf\u003cbr\u003e\n- Reference – Loxone Campus, Austria: https:\/\/www.belimo.com\/mam\/europe\/marketing_communication\/success-stories\/References\/eu_en-gb\/belimo_div_loxone-campus_reference_emea_en-gb.pdf\u003cbr\u003e\n- Reference – Paramount Group, New York, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_paramount-group_success-story_en-us.pdf\u003cbr\u003e\n- Reference – University of Miami, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_university-of-miami_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Arboleda: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_arboleda_success-story_en-us.pdf\u003cbr\u003e\n- Success Story - Bouygues Construction, France: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_bouygues_construction_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Dunn Buildings, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/pressure_independent_valves\/belimo_dunn-buildings_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Embarcadero: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_embarcadero_success-story_en-us.pdf\u003cbr\u003e\n- Success Story - Hillsdale College, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_hillsdale_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Johnson Geo Centre, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_johnson-geo-centre_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Land O'Lakes, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_land-olakes_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Massachusetts Institute of Technology, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_mit-w_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Milano e Torino Complex, Brazil: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_milano-torino_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - Providence College EV, Rhode Island: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_providence-college-ev_success-story_en-us.pdf\u003cbr\u003e\n- Success Story - Sports Entertainment Complex, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_entertainment-complex_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - University of Macedonia, Macedonia: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_university-of-macedonia_success-story_es-us.pdf\u003cbr\u003e\n- Success Story - University of New Brunswick, Canada: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_unb-canada_success-story_en-us.pdf\u003cbr\u003e\n- Success Story – Attleboro High School: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/pressure_independent_valves\/belimo_attleboro-high-school_success-story_en-us.pdf\u003cbr\u003e\n- Success Story – Global Technology Company, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_reference-global-technology-company_success-story_es-us.pdf\u003cbr\u003e\n- Success Story – Passeio 42: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_passeio-42_success-story_en-us.pdf\u003cbr\u003e\n- Success Story – Ransom Everglades, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_ransom-everglades_success-story_en-us.pdf\u003cbr\u003e\n- Success Story – Red Wing School, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_red-wing-school_success-story_es-us.pdf\u003cbr\u003e\n- Success Story – Shands Hospital, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_shands-hospital_success-story-en-us.pdf\u003cbr\u003e\n- Success Story – Tennessee State Building, USA: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_tennessee-state-building_success-story_es-us.pdf\u003cbr\u003e\n- Success Story – Torre Origami, Mexico: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_torre-origami_success-story_es-us.pdf\u003cbr\u003e\n- Success Story – Western University, Ontario: https:\/\/www.belimo.com\/mam\/americas\/marketing_communication\/case_studies\/energy_valves\/belimo_western-university-ontario_success-story_es-us.pdf\u003cbr\u003e\n- Download Selected: https:\/\/www.belimo.com\/us\/shop\/en_US\/Control-Valves\/Energy-Valve\/EV150%2BARX-E-N4HT\/p?code=EV150%2BARX-E+N4HT#download\u003cbr\u003e\n- Go to Download Folder: https:\/\/www.belimo.com\/us\/en_US\/downloadcenter\u003c\/p\u003e","brand":"Belimo","offers":[{"title":"Default Title","offer_id":71434138550525,"sku":"EV150+ARX-E N4HT","price":7270.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0788\/7116\/7229\/files\/PIC_AM_EV4..N4_4C-product_retina.jpg?v=1790701976","url":"https:\/\/pemparts.com\/products\/ev150-arx-e-n4ht","provider":"PEM Parts, Inc.","version":"1.0","type":"link"}